Sistema di Test KEWELL B2000PG-14K-6-700-4-EC battery charge/discharge

da KEWELL
€0,00
Type
B2000PG-14K-6-700-4-EC
Single Channel Rated Power[kW] 3.5 kW

Voltage range -6-6 V

Single Channel Rated
Current[A]
700 A

Channel 4

Dimension (W*D*H) [mm] 600-700-1000

Communication interface LAN, RS485, CANFD *

 

Note: * the communication interfaces are used for integrating peripherals such as environmental chamber and temperature acquisition
instruments.


Cell Charge and Discharge Test System B2000-EC Series

La serie B2000-EC è un sistema efficiente e ad alte prestazioni per i test di carica e scarica delle celle delle batterie. Il sistema di test è caratterizzato da un design modulare, elevata precisione, elevata risposta dinamica, connessione parallela multicanale e alimentazione bidirezionale. Integra l'acquisizione dati e il monitoraggio durante il processo di carica e scarica. La serie B2000-EC trova ampia applicazione nei test EOL e nella ricerca e sviluppo per le celle di batterie di trazione e accumulatori di energia, nonché nei test eseguiti da istituti di ricerca.

Caratteristiche :

-Voltage output range: -6V~6V (optional: -10~10V)
-Current output range: 0~800A
-Min. operating condition interval: 10ms
-Data logging time: 1ms
-Current response: 1ms@10%~90%
-Voltage accuracy: ±0.02%F.S.
-Current accuracy: ±0.02%F.S.
-Temperature sampling: K-type, T-type(-50°C~200°C)
-CV, CC, CP, CR, CCCV, pulse current, pulse power,ramp current, ramp power
-Flexible paralleling: Up to 4800A
-Current switch: 2ms@-90%~90%
-Matrix mode (LUT)
-All-round protection
-Four current ranges
-Real-time monitoring, data and curves
-Negative voltage discharge
-Ripple injection (optional)
-Comm. interface(peripherals): LAN, RS485, CANFD

Normal = Fundamental, Cost-effective
Pro = Fully-featured, Multi-scenario

Output
parameter
Normal  Pro
Charge voltage range 0-6V Voltage range  -6-6V 
Discharge voltage range 0.5-6V
Voltage accuracy ±0.05%F.S. @ 15-35℃ ambient temperature ±0.02%F.S. @ 15-35℃  ambient temperature 
Current accuracy ±0.05%F.S. @ 15-35℃ ambient temperature ±0.02%F.S. @ 15-35℃  ambient temperature 
Power accuracy ±0.1%F.S. @ 15-35℃ ambient temperature ±0.05%F.S. @ 15-35℃  ambient temperature 
Temperature coefficient ±25ppm/℃ ±25ppm/℃
Current response time ≤2ms(10% ~ 90%)@3.5m cable ≤1ms(10%  ~  90%)@3.5m cable
Current switching time ≤4ms(-90% ~+90%)@3.5m cable ≤2ms(-90%  ~+90%)@3.5m cable 
Min operating time                20ms             10ms 
Data record time 10ms 1ms 
One cabinet supports a maximum of 2 channels to perform data logging at the interval of 1ms, whil
e the other channels can record data at an interval  ≥10ms 
Peak efficiency 80% 80% 
Displayed resolution 0.1mV/0.1mA 0.1mV/0.1mA 
Setting resolution 1mV/1mA 1mV/1mA 
Channel parallel Yes Yes


Downloads:

B2000_flyer
B2000_datasheet
B2000PG-EC
B2000NG-EC